MobiGATE is the SMS Gateway for HRWeb.ph

HRweb.ph is a web based Payroll, HRIS, Timekeeping & Solution developed by Sert Technology from the Philippines.

 

MOBITEK® MobiGATE SMS Gateway

HRWeb.ph is using MOBITEK®  MobiGATETM as the SMS Gateway to send out notifications.

 

CASE STUDY

  • HRWeb, web portal, is hosted in a data centre in Singapore, while MOBITEK®  MobiGATETM is located in Sert Technology’s office in Cavite, Philippines.
  • Advantages:-
    • MobiGATE can be placed anywhere on the internet, whether in the data centre, Singapore or in Cavite, Philippines;
    • there are no internet connection to MOBITEK System therefore, all messages sent and received are protected and kept private by Sert Technology; and
    • MobiGATE uses SIM card, support up to 8 SIM cards per unit, with SIM card, the SMS Gateway is directly connected with TELCO via GSM or 3G network without relying on internet.

For more information on MOBITEK®  MobiGATETM , visit its product page.

 

 

How to Solve “You do not have permission to use the bulk load statement”

Applies to: MS SQL Express 2017

Error Message: You do not have permission to use the bulk load statement

Solution: SQL Management Studio (log in as administrator) → Security → Login → Choose username (right-click) → Properties → Server Roles → Check “bulkadmin”

(source: http://stackoverflow.com/questions/32417776/you-do-not-have-permission-to-use-the-bulk-load-statement-error )

How to Prevent Brute Force Attack by Hackers to Gain Access to Your WordPress Site

Problem

To log into a WordPress Site, user name and password are required.

Hacker can obtain user name from the name of author in blog post, then goto WordPress default log-in page — https://your_domain_name.com//wp-admin/ , hacker will guess password to log into your WordPress site, hence “brute force”.

In a minute, if a hacker can guess 10 passwords then in a day, hacker can try 14,400 different passwords (10 x 60 x 24 ) to try to log into your WordPress site.

It is a matter of time, the hacker can guess the correct password.

 

Solution: use “Loginizer Security” plug-in to prevent brute force attack

  1. Install plug-in “Loginizer Security“.
  2. Under “Blacklist”, enter range of IP address that is not in your home country. This will reduce brute force attack significantly.

 

 

 

 

 

Virus Infected E-mail from contact@bioaqriland.com

If you received such e-mail with attachment, delete it immediately as the attachment is a virus/malware/trojan.

 HI,

Please send us quotation for attached.      

 Best Regards. WANG KAI yuen=
   Yuenac@cosco.com
  COSCO Marine Engineering (S) Pte Ltd
 52 Penjuru Lane Singapore 609213
  =

 Tel: +65 6261 8009
 Email: commercial@coscomarine.com.sg
  =

 ....
  =

 Address 16 Raffles Quay=FF0C#36-01 Hong Leong Building=FF0CSingapore 048581
  =

 Phone 65-6226 1900
 =


 Don't print except absolutely necessary

 

Virus Infected E-mail from Adeoti.Famurewa@dhl.com

If you received such e-mail with attachment, delete it immediately as the attachment is a virus/malware/trojan.

Refer to DHL web site for more information — https://www.logistics.dhl/global-en/home/footer/fraud-awareness.html

Dear Sir,

This is to inform you of the arrival of your shipment on the above
Airway bill number and in the attached document through our Worldwide
Parcel Express Service.

THIS SHIPMENT HAS BEEN CONSIDERED DUTIABLE BY THE CUSTOMS SERVICE AND
WOULD BE RELEASED SUBJECT TO THE PAYMENT OF THE TOTAL DUE ON DUTIES AND
TAXES AS ANALYZED IN THE ATTACHED DOCUMENTS AND BELOW INVOICE SUMMARY.

KINDLY EFFECT PAYMENT OF THE TOTAL DUE BELOW WITHIN 7 WORKING DAYS
EFFECTIVE FROM THE DATE THIS LETTER IS RECEIVED AND FORWARD THE PAYMENT
DETAILS . This is to avoid shipment incurring demurrage charge and the
subsequent transfer to Government warehouse after 28 days as required by
regulations.

INVOICE SUMMARY ATTACHED:

ADMINISTRATIVE FEES

Administrative Fees are charged on every clearance as DHL handling
charge. This is 4% of Total Duty (ON THE MINIMUM OF $10.00) and Taxes
and 5% VAT, which should be paid along with duty into our GTB account
provided below.

DEMURRAGE CHARGE

DEMURRAGE CHARGE SHALL COMMENCE 8 WORKING DAYS FROM THE DATE YOUR
SHIPMENT IS SCANNED INTO THE CUSTOMS BOND AND ENDS ON THE DAY DUTY IS
PAID. THIS CHARGE SHOULD BE PAID ALONG WITH TOTAL DUTY TO AVOID DELAY IN
RELEASE OF YOUR PACKAGE. MINIMUM CHARGE $5.00.

PAYMENT DETAILS

PAYMENT MODE

ACCOUNT NUMBER

BRANCH SORTCODE

ACCOUNT NAME

ACCOUNT TYPE

BANK

Online Payment

0138852358

0-58152227

DHL International LTD

Current

stanbic Bank

Cash Payment

0011528581

N/A

DHL International LTD

Current

stanbic Bank

CASH PAYMENTS SHOULD BE MADE THROUGH STANBIC BANK BRANCHES NATIONWIDE.

TO AVOID DELAY IN RELEASE OF YOUR SHIPMENT, ENSURE CORRECT WAYBILL
NUMBER (TRACKING NUMBER) IS CLEARLY INDICATED ON THE BANK COPY OR IN THE
REMARKS DESCRIPTION FIELD FOR ONLINE PAYMENTS AND FORWARD PAYMENT
DETAILS

QUERIES /COMPLAINTS ON CUSTOMS CHARGES

For queries and Complaints on charges should be directed to our customs
Desk through los_duty@dhl.com; losgcsdteam@dhl.com

INFORMATION ON TRADE & CUSTOMS DUTY AND TAXES

For more information on Trade & Customs Duty and Taxes please visit
Customs website www.customs.gov [1]

Yours Faithfully,

Davids Malachi

CUSTOMS CLEARANCE MANAGER

Regards,

ADEOTI FAMUREWA

GATEWAY CUSTOMER SERVICE DESK ADVISOR

DHL EXPRESS

LOS Gateway
International Airport. Nahco Shed,

E-MAIL: adeoti.famuewa@dhl.com

CONFIDENTIALITY NOTICE: This message is from DHL and may contain
confidential business information. It is intended solely for the use of
the individual to whom it is addressed. If you are not the intended
recipient please contact the sender and delete this message and any
attachment from your system. Unauthorized publication, use,
dissemination, forwarding, printing or copying of this E-Mail and its
attachments is strictly prohibited. CONFIDENTIALITY NOTICE: This message
is from DHL and may contain confidential business information. It is
intended solely for the use of the individual to whom it is addressed.
If you are not the intended recipient please contact the sender and
delete this message and any attachment from your system. Unauthorized
publication, use, dissemination, forwarding, printing or copying of this
E-Mail and its attachments is strictly prohibited.

How to Make Civilization IV Run in Windows 8.1 64-bit

Civilization IV will give you these error messages in Windows 8.1 64-bit:-

  • “The program can’t start because D3DX9_32.DLL is missing from your computer. Try reinstalling the progrom to fix the problem”; and
  • “Error loading shader libraries”

If these solutions do not work:-

  1. re-installing Civilization IV in “compatibility mode” as mentioned in Microsoft Community; or
  2. running “dxwebsetup.exe” to re-install DirectX version 9 as mentioned in Microsoft Community;

Then these will 100% solve the problems:-

  1. download “d3dx9_32.dll”, unzip and copy to folder “C:\Windows\SysWOW64”; and
  2. download “d3dx9_31.dll”, unzip and copy to folder “C:\Windows\SysWOW64”; this dll will solve “Error loading shader libraries”

This is because Windows 8.1 64-bit does not have “d3dx9_32.dll” and “d3dx9_31.dll” by default.

Source: https://forums.civfanatics.com/threads/to-those-with-d3dx9_32-dll-problems.232577/page-3

Reasons:-

  • Windows 8.1 64-bit by default is installed with DirectX 11 and it does not have all the dll files (d3dx9_xx.dll) of DirectX 9;
  • DirectX 9 is required to run old games such as Civilization IV  that support Windows Vista and below.

How to Solve the Problem of “mcpu.exe – Application Error : The application was unable to start correctly (0xc0000142)”

Applies To:

  • MOBITEK MobiGATE Model SG-B-4-L / SG-B-8-L series (model having LAN port)
  • VCOM version older than 4.5.11

 

Problem: Windows applications not able to run or the whole PC/server will hang.

  1. In “Windows Task Managmer”, “mcpu.exe” will appear everytime VCOM connects to modem in MobiGATE then will disappear:-
  2. After running VCOM for few days, Windows will show an error message “mcpu.exe – Application Error : The application was unable to start correctly (0xc0000142)”:-

  3. “Windows Task Manager” shows high memory usage:-
  4. This will caused other Windows applications not able to run or the whole PC/server will hang:-

 

Solution: VCOM version older than 4.5.11 has memory leak, causing high memory usage. Therefore, need to install version 4.5.11.