Author Archives: Administrator

Dell OptiPlex 9030 All in One Has Replaced 9020

OptiPlex 9020 All-in-One with Optional Touch Screen

New OptiPlex 9030 All-in-One with Optional Touch Screen

Dell OptiPlex 9030 All in One Has Replaced 9020.

The Differences between Dell OptiPlex 9020 All in One and Dell OptiPlex 9030 All in One are highlighted in “BOLD

OptiPlex 9020 All in One OptiPlex 9030 AIO CTO
Components1 Up to 90 % efficient PSU Base 58,4cm (23 INCH) Non-touch
without Camera

1 Energy efficient chassis

1 Intel Core I5-4570S Processor (Quad Core, 2.90GHz Turbo,
6MB, w/ HD Graphics 4600)

1 Non-Touch LCD, Dell OptiPlex AIO

1 8GB (2x4GB) 1600MHz DDR3L

1 1TB 3.5inch Serial ATA (7,200 Rpm) Hard Drive

1 Heatsink for Non-Touch LCD, AIO

1 8X Max Slimline DVD+/-RW

1 System Power Cord
(UK/MY/SG/HK/Bangladesh/Brunei/Pakistan/Sri Lanka/Maldives)

1 Intrusion Switch

1 Integration Information

1 Order Ready ProSupport Tag

1 ProSupport Service Label

1 Bracket for 3.5 inch hard drive and No hard drive

1 Intel Core I5 vPro Label

1 Intel Integrated Graphics, Dell OptiPlex

1 No Wireless

1 VESA Mount Bracket, Non-Touch

1 Integrated Basic Stand

1 Dell MS111 USB Optical Mouse

1 US English (QWERTY) Dell KB212-B QuietKey USB Keyboard
Black

1 Dell Applications for Windows 7

Software

1 Windows Live

1 Windows(R) 7 Professional 64 bit (English) (EMRP)

1 Microsoft Office 2013 Trial

1 Dell Backup and Recovery Basic 1.6

1 Visit www.dell.com/encryption

1 Not Selected in this Configuration

1 Dell Data Protection Security Tools Digital Delivery/DT

1 Thank you for buying Dell

1 No Anti-Virus software

Service

1 3Yr ProSupport: NBD Onsite Service

1 ProSupport: 7×24 Technical Support & Assistance: 3Yr

1 Dell ProSupport for Software, No DDPE Encryption SW

Components1 Intel Core i5-4590S Processor (Quad Core, 6MB, 3.00GHz
w/HD4600 Graphics)  

1 ENERGY STAR Version 6.0

1 Non-Touch LCD, Dell OptiPlex AIO

1 No Camera Software

1 Up to 90% efficient PSU Base 58.4cm (23 INCH) Non-touch
without Camera, Integrated

1 4GB (1x4GB) 1600MHz DDR3L

1 1TB 2.5inch SATA (5,400 Rpm) Hard Drive

1 No Additional Hard Drive

1 No Intel Technology enabled

1 Heat Sink, Dell OptiPlex 9030 AIO

1 8x Slimline DVD+/-RW Drive

1 System Power Cord
(UK/MY/SG/HK/Bangladesh/Brunei/Pakistan/Sri Lanka/Maldives)

1 Intel Core I5 Label

1 Intel Integrated Graphics, Dell OptiPlex

1 No Wireless

1 Integrated Basic Stand

1 Dell MS111 USB Optical Mouse

1 US English (QWERTY) Dell KB212-B QuietKey USB Keyboard
Black

1 Dell Applications for Windows 7

Software

1 Windows(R) 7 Professional 64 bit (English) (EMRP)

1 Microsoft Office 2013 Trial

1 No Out-of-Band Systems Management

1 Dell Backup and Recovery Basic 1.6

1 Dell Data Protection | Security Tools Digital Delivery/DT

1 My Dell, Digital Delivery

1 No Anti-Virus software

Service

1 3Yr ProSupport: NBD Onsite Service

1 ProSupport: 7×24 Technical Support & Assistance: 3Yr

1 Dell ProSupport for Software, No DDPE Encryption SW

MobiGATE Has a Powerful SMS Engine

Compare with modem pool that is made in China, MobiGATE has a powerful MOBITEK SMS Engine — Enterprise Edition, having these features:-

  1. routing by prefix
  2. manual routing
  3. load balancing
  4. auto reconnection to modem and database
  5. etc.

The above features cannot be done via AT command.

More Information

Each GSM Channel/SIM Card/Modem of MobiGATE Has Its Own IP Address

We need multiple sim modems for the different providers here in the Philippines.  We are already using wavecom single sim modems.  We need multiple sims modem wherein we can assign ip address for each sim. Do you have such product?

Yes, we have, we recommend MobiGATE Model: SG-4-E that supports 4 GSM Channels/SIM Cards/Modems, each of the channel can be assigned to an IP address:-

  • modem 1 => 192.168.1.10:8001
  • modem 2 => 192.168.1.10:8002
  • modem 3 => 192.168.1.10:8003
  • modem 4 => 192.168.1.10:8004

On PC side, you will need to install a virtual com port driver that will map a COM port to the IP address, e.g.:-

  • COM Port no. 11 => 192.168.1.10:8001
  • COM Port no. 12 => 192.168.1.10:8002
  • COM Port no. 13 => 192.168.1.10:8003
  • COM Port no. 14 => 192.168.1.10:8004

You can use the following communication methods:-

  1. SQL via MOBITEK SMS ENGINE
  2. AT command via TCP/IP (you do not need to specify the IP address as the virtual com port has mapped the comport with IP address for you)

Note: the above model SG-4-E was an old model.

More Information

MOBIGATE — How to Send and Read SMS

SMS_GATEWAY

MOBIGATE

These are the protocols supported by MOBIGATE SG-4-E to send and read SMS:-

  1. SQL
    • to send out SMS: Insert into Outbox (msg_id, message, destination) values (‘1’, ‘Hello!’, ‘+60172233111’)
    • to read SMS: Select * from Inbox where read_status = ‘N’
  2. MOBITEK SMS API over TCP/IP
  3. AT Command over TCP/IP

 MOBIGATE SPECIFICATION

How to Scale-Up SMS Gateway

Is there another model that is capable of supporting more than 4 modems?

There are 2 options:-

  1. MobiGATE; or
  2. Modem Hub

We recommend MobiGATE as the solution. 1 unit MobiGATE has built-in:-

  1. 4 SMS Modems/SIM cards; and
  2. Modem Hub

To scale-up (increase number of modems), add more units of MobiGATE, model: SG-4-E where the connectivity is ethernet (LAN port):-

  • all MOBIGATEs are connected to <-> switch/LAN <-> Windows server
  • 1 Windows server is able to control multiple units of MOBIGATE
    • e.g. 1 server can control 10 units of MOBIGATE (or 40 units of Modems)
  • 1 server, 1 SMS Engine, 1 config.xml, 1 database <-> multiple units of MOBIGATE

Continue reading

How to Set-Up a Air-Time Reload Service for Customers in Singapore to Reload MAXIS Air-Time?

I’d like to do Maxis E-Load & Digi Flexi E-Load from overseas like Korea, Singapore. Please let me know the possibility.

The set-up is as follows:-

  • The MOBITEK Q24 STK MODEM will be located in Malaysia with Maxis e-load SIM card inserted
  • MOBITEK Q24 SMS MODEM will be located in Malaysia with Singapore SIM card, roaming enable, number is +65923xxxxx
  • customer in Singapore will send SMS to +65923xxxxx with message containing command to reload
  • your application will read the incoming SMS reload request from MOBITEK Q24 SMS MODEM
  • your application will then instruct MOBITEK Q24 STK MODEM to begin reload process

For more information about:-

  1. MOBITEK Q24 STK MODEM and MOBITEK STK API
  2. MOBITEK Q24 SMS MODEM and MOBITEK SMS GATEWAY DEVELOPMENT KIT

MOBITEK Q24 SMS MODEM in Environmental Monitoring System (EMS)

MOBITEK Q24 SMS Modem

MOBITEK Q24 SMS Modem

 

Our MOBITEK Q24 SMS MODEM is used by INFOCONNECT’s EMS.

Here is an introduction on EMS by our partner Mr. Ooi Chee Thim, Director of Sales, INFOCONNECT:

Nowadays, modern data centers consist rows and rows of server & network racks. Within the racks, there are high powered servers which generate lots of heat. The number one problem in a data center is HEAT nowadays. Thus, monitoring and managing the temperature inside the rack to the manufacturer’s recommended operating environment is a big challenge. Every electronic equipment will operate best as long as the temperature does not exceed manufacturer’s specified operating environment. We all know that. However, the current method of doing show is cumbersome & messy. It has lots of constraints. The whole problem points to the basis that it is a ‘wired’ solution. Wired technology is becoming a ‘sunset’ technology. The data center can do with less or no wires. The current data center is already congested with wires running below the raised floors, along cable trays and/or conduits. It is very messy. It is difficult to manage. It has no investment protection. Thus, it is a big problem for wired technology.

Continue reading

How does MOBTEK STK MODEM HUB, STKMH-EP432 model work?

Note: this post has been superseded by http://mobitek-system.com/blog/2015/01/how-does-mobtek-q24-stk-modem-hub-model-stkmh-ep432-c-work/

MOBITEK STK MODEM HUB

Basically, there are 4 STK MODEM in STKMH-EP432, and each of them is assigned to an IP address:-

  • modem 1 => 192.168.1.10:8001
  • modem 2 => 192.168.1.10:8002
  • modem 3 => 192.168.1.10:8003
  • modem 4 => 192.168.1.10:800

On PC side, you will need to install a virtual com port driver that will map com port to the IP address, e.g.:-

  • COM Port no. 11 => 192.168.1.10:8001
  • COM Port no. 12 => 192.168.1.10:8002
  • COM Port no. 13 => 192.168.1.10:8003
  • COM Port no. 14 => 192.168.1.10:8004

Then your Reload System/Software communicates with the COM port number, e.g.:-

  • Reload1.exe => MobitekSTKAPI.dll => DisplayMainMenu() => COM Port no. 11
  • Reload2.exe => MobitekSTKAPI.dll => DisplayMainMenu() => COM Port no. 12
  • Reload3.exe => MobitekSTKAPI.dll => DisplayMainMenu() => COM Port no. 13
  • Reload4.exe => MobitekSTKAPI.dll => DisplayMainMenu() => COM Port no. 14

Or if you are using multi-threading, then

  • Reload.exe => thread no. 1 => MobitekSTKAPI.dll => DisplayMainMenu() => COM Port no. 11
  • Reload.exe => thread no. 2 => MobitekSTKAPI.dll => DisplayMainMenu() => COM Port no. 12
  • Reload.exe => thread no. 3 => MobitekSTKAPI.dll => DisplayMainMenu() => COM Port no. 13
  • Reload.exe => thread no. 4 => MobitekSTKAPI.dll => DisplayMainMenu() => COM Port no. 14