Test Result of Whether Our MOBITEK Q24 GSM MODEM is Compatible with SMSLib

MOBITEK Q24 USB
MOBITEK Q24 GSM Modem is compatible with SMSLib

 

Tested enviroment:
– Window XP 32bit
– Java Eclispe Version: 3.4.0

 

Tested:
– Finding com port using “commTest.java” -> ( successful )
– Receiving SMS using “ReadMessages.java” -> ( successful )
– Sending SMS using “SendMessage.java” ->( successful )

 

Below are log files for the java files.

MOBITEK Q24 SMS MODEM in Environmental Monitoring System (EMS)

MOBITEK Q24 SMS Modem

MOBITEK Q24 SMS Modem

 

Our MOBITEK Q24 SMS MODEM is used by INFOCONNECT’s EMS.

Here is an introduction on EMS by our partner Mr. Ooi Chee Thim, Director of Sales, INFOCONNECT:

Nowadays, modern data centers consist rows and rows of server & network racks. Within the racks, there are high powered servers which generate lots of heat. The number one problem in a data center is HEAT nowadays. Thus, monitoring and managing the temperature inside the rack to the manufacturer’s recommended operating environment is a big challenge. Every electronic equipment will operate best as long as the temperature does not exceed manufacturer’s specified operating environment. We all know that. However, the current method of doing show is cumbersome & messy. It has lots of constraints. The whole problem points to the basis that it is a ‘wired’ solution. Wired technology is becoming a ‘sunset’ technology. The data center can do with less or no wires. The current data center is already congested with wires running below the raised floors, along cable trays and/or conduits. It is very messy. It is difficult to manage. It has no investment protection. Thus, it is a big problem for wired technology.

Continue reading

How does MOBTEK STK MODEM HUB, STKMH-EP432 model work?

Note: this post has been superseded by https://mobitek-system.com/blog/2015/01/how-does-mobtek-q24-stk-modem-hub-model-stkmh-ep432-c-work/

MOBITEK STK MODEM HUB

Basically, there are 4 STK MODEM in STKMH-EP432, and each of them is assigned to an IP address:-

  • modem 1 => 192.168.1.10:8001
  • modem 2 => 192.168.1.10:8002
  • modem 3 => 192.168.1.10:8003
  • modem 4 => 192.168.1.10:800

On PC side, you will need to install a virtual com port driver that will map com port to the IP address, e.g.:-

  • COM Port no. 11 => 192.168.1.10:8001
  • COM Port no. 12 => 192.168.1.10:8002
  • COM Port no. 13 => 192.168.1.10:8003
  • COM Port no. 14 => 192.168.1.10:8004

Then your Reload System/Software communicates with the COM port number, e.g.:-

  • Reload1.exe => MobitekSTKAPI.dll => DisplayMainMenu() => COM Port no. 11
  • Reload2.exe => MobitekSTKAPI.dll => DisplayMainMenu() => COM Port no. 12
  • Reload3.exe => MobitekSTKAPI.dll => DisplayMainMenu() => COM Port no. 13
  • Reload4.exe => MobitekSTKAPI.dll => DisplayMainMenu() => COM Port no. 14

Or if you are using multi-threading, then

  • Reload.exe => thread no. 1 => MobitekSTKAPI.dll => DisplayMainMenu() => COM Port no. 11
  • Reload.exe => thread no. 2 => MobitekSTKAPI.dll => DisplayMainMenu() => COM Port no. 12
  • Reload.exe => thread no. 3 => MobitekSTKAPI.dll => DisplayMainMenu() => COM Port no. 13
  • Reload.exe => thread no. 4 => MobitekSTKAPI.dll => DisplayMainMenu() => COM Port no. 14